01
Environmentally Responsible Technology
Zero ozone depletion potential and zero global warming potential of the extinguishing agent.
The Next Generation of Aerosol Fire Suppression
GENEFIRE develops advanced condensed aerosol fire suppression solutions for industrial, commercial and specialized applications.
Explore Products01 — About GENEFIRE
GENEFIRE condensed aerosol fire suppression systems are engineered for rapid and effective fire suppression while minimizing impact on protected equipment and the environment.
Compact design and flexible installation make GENEFIRE suitable for a wide range of protected spaces and equipment.
High extinguishing efficiency, combined with optimized construction, enables exceptionally compact and lightweight generators with a long service life.
02 — How It Works
Fire requires three basic elements to ignite: fuel, heat and an oxidizing agent such as oxygen. Once combustion begins, a fourth element — a self-sustaining chemical chain reaction — allows the fire to continue.
Together, these four elements form the Fire Tetrahedron:
FUEL · HEAT · OXYGEN · CHAIN REACTION
Removing or suppressing any one of these elements can interrupt the combustion process and extinguish the fire.
GENEFIRE primarily targets the chemical chain reaction, disrupting the combustion process and rapidly suppressing the fire.
GENEFIRE generators contain a solid aerosol-forming compound stored in a non-pressurized state. Upon activation, a controlled chemical reaction generates a highly dispersed fire-extinguishing aerosol.
The aerosol rapidly spreads throughout the protected space and interferes with the chemical chain reaction that sustains combustion, effectively suppressing the fire.
The extinguishing mechanism does not rely on oxygen depletion.
Fine aerosol particles remain suspended after discharge, helping to reduce the risk of re-ignition.
GENEFIRE TARGETS THE CHAIN REACTION.
GENEFIRE advanced condensed aerosol technology interrupts the chemical chain reaction that sustains combustion — without relying on oxygen depletion.
03 — Why GENEFIRE
Compact design and flexible installation make GENEFIRE suitable for a wide range of protected spaces and equipment.
01
Zero ozone depletion potential and zero global warming potential of the extinguishing agent.
02
Rapid and effective fire suppression with exceptionally low extinguishing application density.
03
Designed for a wide range of industrial, commercial and specialized applications.
04
Compact, efficient technology designed to reduce installation and lifecycle requirements.
05
Optimized construction enables exceptionally compact and lightweight generators.
06
Compact design and flexible installation for a wide range of protected spaces and equipment.
07
Advanced design helps control aerosol discharge temperature without compromising suppression performance.
08
Solid aerosol-forming compound is stored safely in a non-pressurized state until activation.
04 — Products / Solutions
GENEFIRE develops advanced condensed aerosol fire suppression solutions for industrial, commercial and specialized applications.
Manual activation
AGC Mass
100 g
Mass (±10%)
200 g
Protected Volume
5 m³
Discharge Time
50 sec
Size
200 × 35 mm
AGC Mass
100 g
Mass (±10%)
360 g
Protected Volume
5 m³
Discharge Time
50 sec
Size
340 × 32 mm
AGC Mass
500 g
Mass (±10%)
1340 g
Protected Volume
25 m³
Discharge Time
40 sec
Size
300 × 160 mm
Thermal and electrical initiation.
AGC Mass
5 / 10 g
Mass (±10%)
80 / 85 g
Protected Volume
0.25 / 0.5 m³
Discharge Time
10 / 15 sec
Size
115 × 19 mm
AGC Mass
25 g
Mass (±10%)
72 g
Protected Volume
1.25 m³
Discharge Time
14 sec
Size
132 × 32 mm
AGC Mass
50 g
Mass (±10%)
113 g
Protected Volume
2.5 m³
Discharge Time
27 sec
Size
162 × 32 mm
AGC Mass
100 g
Mass (±10%)
425 g
Protected Volume
5 m³
Discharge Time
50 sec
Size
227 × 32 mm
Wall or ceiling mounting
AGC Mass
300 g
Mass (±10%)
825 g
Protected Volume
15 m³
Discharge Time
24 sec
Size
181 × 90 mm
AGC Mass
500 g
Mass (±10%)
1025 g
Protected Volume
25 m³
Discharge Time
35 sec
Size
213 × 90 mm
AGC Mass
750 g
Mass (±10%)
1265 g
Protected Volume
37.5 m³
Discharge Time
48 sec
Size
243 × 90 mm
AGC Mass
1500 g
Mass (±10%)
4700 g
Protected Volume
75 m³
Discharge Time
35 sec
Size
218 × 190 mm
05 — Applications
06 — Eco-Friendly Technology
GENEFIRE condensed aerosol technology is designed with environmental responsibility in mind, offering zero ozone depletion potential (ODP) and zero global warming potential (GWP) of the extinguishing agent.
GENEFIRE aerosol fire suppression does not rely on oxygen depletion.
07 — Compliance
GENEFIRE products are tested and documented in accordance with applicable fire safety requirements. Our international certification program is continuously expanding to support GENEFIRE applications across global markets.
In Progress
European Certification
GENEFIRE is currently undergoing European conformity assessment and certification according to EN 15276-1 for condensed aerosol fire extinguishing systems.
✓ Certified
Eurasian Economic Union
GENEFIRE condensed aerosol fire extinguishing generators are certified for conformity with applicable EAEU fire safety requirements.
✓ Tested
Accredited Laboratories
GENEFIRE products have undergone fire performance and technical testing by independent accredited laboratories in accordance with relevant international standards.
✓ Documented
Safety Documentation
Technical documentation, installation instructions and safety documentation are available for GENEFIRE products and are continuously updated in line with regulatory requirements.
MANAGEMENT SYSTEMS
GENEFIRE manufacturing operations are supported by certified quality, environmental and occupational health & safety management systems.
Quality Management System
Environmental Management System
Occupational Health & Safety Management System
08 — Global Contact
Prague
Czech Republic
Astana
Republic of Kazakhstan
New Delhi
India